SRS QA Phantom that provides Fully-Anthropomorphic, High-Definition imaging capability for IGRT QA with MR, CT, kV and MV modalities.
End-to-End System Testing
The anthropomorphic features include skull, brain, vertebrae, sinus cavities, cortical and trabecular bone structure, larynx, trachea, and oral cavities.
MR-Visible
Cast from new proprietary materials, the entirety of LUCY MR's soft tissue anatomy is MR-Visible, providing truly comprehensive End-To-End SRS QA across MR-Guided and MR-Simulation systems.
SRS QA Commissioning
Confirm accurate setup and function of SRS planning and delivery systems with MR-Guided capability.
TG-101 and TG-135
Supports multiple AAPM TG SRS testing protocols through:
- Complete End-To-End Tests
- Winston-Lutz test
- Isocentric Verification
- Bony Anatomy Localization
- Laser Alignment
- Localization / Repositioning with Couch Shifts
- Patient Orientation / Image Transfer QA
- IGRT QA for MR, X-Ray and On-board kV and MV images, including CBCT
- OSMS or SGRT Optical System Positioning QA
- MR/CT Image Fusion Multiple Met Dosimetry
3D Film Target Inserts
3D Target Inserts are bisected by two orthogonal film planes
Posterior 3D Film Target Insert
- 0.625" Spherical Target
- Bisected by two orthogonal film planes
Anterior 3D Film Target Insert
- 1.0" Spherical Target
- Bisected by two orthogonal film planes
Specifications
Jump to:
| Anterior Section | 6 cm3 Insert Pocket |
| Posterior Section | 4 cm3 Insert Pocket, Large Coronal Film Plane, and Ion Chamber Cavity |
| Anthropomorphic Anatomy | Size, Shape, and Weight similar to human head. |
| Skull, brain, spinal cord, oral and nasal cavities, and simulates cortical and trabecular bone densities in the skull and spinal cord. | |
| Targets | Up to 13 distinct targets |
Resources
Webinars and Videos
Publications
- Independent Secondary Dose Calculation for Patient-Specific Quality Assurance: Quantitative Benefit of Monte–Carlo and Custom Beam Modeling
- Routine Machine Quality Assurance Tests for a Self Shielded Gyroscopic Radiosurgery System
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Whats New ESTRO 2025
- Transforming Radiation Therapy: Standard Imaging's Adaptivo In Vivo EPID Dosimetry Solution for Personalized Treatment Precision--A Comprehensive Clinical Use Case Review
- Evaluation of the Exradin A19 Ion Chamber for Reference Dosimetry in Megavoltage Photon Beams
- Evaluation of a Water-proof, Homogeneous Farmer-Type Ion Chamber for Orthovoltage and High Energy X-Rays and Electron Beams
- Commissioning and Cross-Comparison of Four Scanning Water Tanks
- Validation of the Acuros XB dose calculation algorithm versus Monte Carlo for clinical treatment plans
We Are Here to Help
Get Pricing for DoseView™ 3D
Request a Quote
Your Wisconsin Rep is
Here to Help
Change Location
Contact Us
Online Chat
We encourage you to contact our customer service and support team.
Customer Care
For best service, login to your account.