608-831-0025 (International)
800-261-4446 (U.S.)
Modality
Category
Ideal Chamber for Long Source Trains
Why Perform Independent Verification?
AAPM TG-56, TG-40 and TRS-398 recommend independent verification of source strengths. Without independent calibration, centers in the U.S. may be forgoing reimbursement income.
Superior Functionality
An exceptionally long 100 mm sweet spot, unmatched in other chambers, accommodates long source trains and wires. Calibrates individual and multiple isotopes. Outstanding versatility, use one chamber for many isotopes. Source holders available for most existing sources.
Assurance is Confidence
Satisfies NRC requirements and TG-60 quality assurance requirements for IVB source strength verification. Precise and accurate calibration of HDR and LDR Iridium, Iodine, Palladium, Cesium, and Strontium brachytherapy source activities.
Download the IVB 1000 Well Chamber Datasheet
Specifications
| Dimensions | |
|---|---|
| Height | 25.9 cm |
| Diameter | 10.2 cm |
| Insert Diameter | 3.5 cm |
| Insert Height | 22.4 cm |
| Weight | 3.5 kg |
| Product Standards | |
| IEC 60601-1, IEC 60601-1-2 | |
| Operating Parameters | |
| Temperature | 10 to 40 °C |
| Relative Humidity | 20 to 80% non-condensing |
| Pressure | 650 to 770 mmHg |
| Storage Parameters | |
| Temperature | -15 to 50 °C |
| Relative Humidity | 10 to 95% non-condensing |
| Pressure | 600 to 800 mmHg |
Resources
Webinars and Videos
Publications
- Independent Secondary Dose Calculation for Patient-Specific Quality Assurance: Quantitative Benefit of Monte–Carlo and Custom Beam Modeling
- Routine Machine Quality Assurance Tests for a Self Shielded Gyroscopic Radiosurgery System
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Whats New ESTRO 2025
- Transforming Radiation Therapy: Standard Imaging's Adaptivo In Vivo EPID Dosimetry Solution for Personalized Treatment Precision--A Comprehensive Clinical Use Case Review
- Evaluation of the Exradin A19 Ion Chamber for Reference Dosimetry in Megavoltage Photon Beams
- Evaluation of a Water-proof, Homogeneous Farmer-Type Ion Chamber for Orthovoltage and High Energy X-Rays and Electron Beams
- Commissioning and Cross-Comparison of Four Scanning Water Tanks
- Validation of the Acuros XB dose calculation algorithm versus Monte Carlo for clinical treatment plans
We Are Here to Help
Your Wisconsin Rep is
Here to Help
Change Location
Contact Us
Online Chat
We encourage you to contact our customer service and support team.
Customer Care