608-831-0025 (International)
800-261-4446 (U.S.)
The Most Trusted Name in Second Check Technology
Thorough Stereotactic QA
Calculate and confirm cone-based or MLC-based stereotactic treatments, including conformal and dynamic arcs. Create specific beam models in the physics module to increase small field accurately.
Brachytherapy Plan Verification Module
Quickly and easily validate HDR and LDR plans. Review individual sources’ contributions and positions.
Comprehensive Plan Verification
Inclusion of a 3-source model provides accurate dose calculations, for both IMRT and VMAT. Point dose and MU verification as well as fluence comparison analysis.
3-Source Model
The 3-Source Model was developed at Stanford University to accurately calculate the contribution to dose from the head scatter no matter the field size, shape or the point of calculation in the field.
Intuitive Computing
After import of plan, structures and CT images; automatic effective depth calculations are performed to account for patient heterogeneity.
Structure Specific Analysis
Review your dose point variation aided by anatomical structures of interest such as the PTV or a critical structure for in-depth analysis of your plan.
Quick and Easy Plan Review
Field by field gamma analysis maps as well as histograms aid in focused plan review.
Advanced Features
IMSure QA Software supports open beams, FFF beams, .decimal compensators, stereotactic cones & wedged beams, allowing you to streamline your plan QA.
Download the IMSure QA Software Brochure
Specifications
| IMSure Software/computer Requirements | |
|---|---|
| Operating System | Windows® 10 Professional, 64 bit recommended |
| Processor | Dual Core, 1 GHz; Quad Core, 2 GHz Recommended |
| Memory | 32-bit OS: 2 GB, 4 GB Recommended; 64-bit OS: 4 GB, 8 GB Recommended |
| Runtime Environment | Visual C++ 2010 Runtime |
| Hard Drive | 32 GB or greater, 3 GB free space for initial software installation. |
| Hard Drive | Sufficient free space to store the input RT Plan, Structures, and Image files as required. |
| Hard Drive | 25% free space recommended. |
| Screen Resolution | 1024 x 768 or greater |
| Optical Drive | Compact Disc (CD) or Digital Versatile Disc (DVD) |
| Connectivity | IPv4 LAN, 100 Mbit/s or greater |
Resources
Webinars and Videos
Publications
- Independent Secondary Dose Calculation for Patient-Specific Quality Assurance: Quantitative Benefit of Monte–Carlo and Custom Beam Modeling
- Routine Machine Quality Assurance Tests for a Self Shielded Gyroscopic Radiosurgery System
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Whats New ESTRO 2025
- Transforming Radiation Therapy: Standard Imaging's Adaptivo In Vivo EPID Dosimetry Solution for Personalized Treatment Precision--A Comprehensive Clinical Use Case Review
- Evaluation of the Exradin A19 Ion Chamber for Reference Dosimetry in Megavoltage Photon Beams
- Evaluation of a Water-proof, Homogeneous Farmer-Type Ion Chamber for Orthovoltage and High Energy X-Rays and Electron Beams
- Commissioning and Cross-Comparison of Four Scanning Water Tanks
- Validation of the Acuros XB dose calculation algorithm versus Monte Carlo for clinical treatment plans
We Are Here to Help
Your Wisconsin Rep is
Here to Help
Change Location
Contact Us
Online Chat
We encourage you to contact our customer service and support team.
Customer Care
For best service, login to your account.