| Automated Image-Based Tests | |
|---|---|
| TG-142 monthly Planar MV and kV imagers | |
| TG-142 monthly Cone-Beam CT imager | |
| TG-142 monthly light/radiation field coincidence | |
| TG-142 annual gantry, collimator and couch starshot | |
| TG-142 annual radiation & mechanical isocenter coincidence (Winston-Lutz test) | |
| TG-142 weekly MLC picket fence test | |
| TG-142 monthly MLC leaf position accuracy | |
| TG-142 monthly MLC travel speed | |
| TG-142 monthly MLC setting vs. radiation field for two patterns | |
| TG-142 Annual MLC transmission | |
| TG-142 Annual MLC leaf position repeatability | |
| TG-142 Annual MLC segmental and moving window IMRT | |
| Beyond TG-142 | |
| Advanced CT analysis | |
| Detect and report CatPhan setup for rotation, tilt and yaw | |
| Assymetric field test (using FC-2 phantom) | |
| Varian VMAT Test 2 and Test 3 | |
| DICOM and TIFF image support | |
| Automatic placement of ROIs by phantom type | |
| Preset templates include image-based tests | |
| Selectable test frequency | |
| Supports SI imaging phantoms | |
| Supports non-SI imaging phantoms | |
| Dashboards | |
| Integrates with QA Pilot | |
Resources
Webinars and Videos
Publications
- Beyond MU Checks: IMSure 3D™ with SciMoCa™ for Independent Second Dose Check
- Independent Secondary Dose Calculation for Patient-Specific Quality Assurance: Quantitative Benefit of Monte–Carlo and Custom Beam Modeling
- Routine Machine Quality Assurance Tests for a Self Shielded Gyroscopic Radiosurgery System
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Whats New ESTRO 2025
- Transforming Radiation Therapy: Standard Imaging's Adaptivo In Vivo EPID Dosimetry Solution for Personalized Treatment Precision--A Comprehensive Clinical Use Case Review
- Evaluation of the Exradin A19 Ion Chamber for Reference Dosimetry in Megavoltage Photon Beams
- Evaluation of a Water-proof, Homogeneous Farmer-Type Ion Chamber for Orthovoltage and High Energy X-Rays and Electron Beams
- Commissioning and Cross-Comparison of Four Scanning Water Tanks
We Are Here to Help
Get Pricing for QA Pilot™ with PIPSpro™ AutoPilot
Your Wisconsin Rep is Here to Help Change Location
Change Location
Contact Us
Online Chat
We encourage you to contact our customer service and support team.
Customer Care
For best service, login to your account.