Monte Carlo Accuracy Unlocks Tighter QA — Now Demonstrated by Latest Study
A 2025 study confirms Monte Carlo secondary dose calculation improves accuracy and reduces false positives — the power behind IMSure™ 3D.
Empower Your Pre-Treatment QA
Monte Carlo Accuracy
The Monte Carlo algorithm is the gold standard for patient specific QA calculation accuracy. Custom machine-specific beam models ensure the highest accuracy.
Absolute Automation
Automated, time-saving workflow produces 3D dose calculations in minutes with reliable results regarding treatment plan quality.
Quick Calculations
Proprietary multi-core CPU based variance reduction allows for calculation times of around a minute.
Time-saving QA Routine
Software easily identifies errors and provides tools for an intuitive, comprehensive analysis. Quickly and easily assess plans from anywhere using the web-based interface.
Maximize Monte Carlo
Supports all major treatment machines:
Powered by SciMoCa engine.
- Elekta®
- Varian® (including Halcyon™ and Ethos™)
- Siemens®
- Accuray®
- TomoTherapy®
- Radixact®
- CyberKnife®-systems
- ZAP-X®
Download the IMSure 3D Brochure
Specifications
| For optimal system performance, the following are the recommended specifications for the server on which IMSure 3D™ Software will be installed: | |
|---|---|
| CPU | x64-based processors 8C/16T, 1.4 GHz or faster |
| RAM | 20 GB of RAM |
| Free Hard Disk Space | 20 GB (installation) |
| Operating System | Windows** Server 2012 R2 Standard or newer with IIS enabled (**Windows is a registered trademark of Microsoft Corporation.) |
| Software | .NET 4.6.2, .NET 3.5 (Windows Server 2016+) IIS |
| Database | Microsoft SQL Server 2012 Standard or newer |
| Monitor | Medical grade with minimum native display resolution of 1024x768 and 32-bit color |
| Input Device | Standard keyboard and wheeled mouse |
| Language | English (US) or English (UK) |
| The following are the minimum recommended specifications* for the server on which IMSure 3D™ Software will be installed: | |
| CPU | x64-based processors 4C/8T, 1.4 GHz or faster |
| RAM | 12 GB of RAM |
| Free Hard Disk Space | 20 GB (Installation) |
| Operating System | Windows** Server 2012 R2 Standard or newer with IIS enabled |
| Software | .NET 4.6.2, .NET 3.5 (Windows Server 2016+) IIS |
| Database | Medical grade with minimum native display resolution of 1024x768 and 32-bit color |
| Input Device | Standard keyboard and wheeled mouse |
| Language | English (US) or English (UK) |
| *Minimum specifications will allow users to run typical patient data using a “Fast” Minimum Uncertainty setting with a grid voxel size of 3mm x 3mm x 3mm. | |
| IMSure 3D calculates dose for 3D conformal, IMRT, VMAT, SRS, SRS cones, SBRT (MLC-shaped treatment fields for photon plans), TomoTherapy, Halcyon, Electron, ZAP-X, and CyberKnife (cones, Iris, and MLC) plans. The following requirements are stipulated: | |
| All beams of a treatment plan are assumed to be delivered by the same treatment machine. | |
| All control points of a single beam are assumed to be delivered with the same beam energy. | |
| DICOM plans that do not adhere to these stipulations are rejected. | |
Resources
Webinars and Videos
Publications
- Independent Secondary Dose Calculation for Patient-Specific Quality Assurance: Quantitative Benefit of Monte–Carlo and Custom Beam Modeling
- Routine Machine Quality Assurance Tests for a Self Shielded Gyroscopic Radiosurgery System
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Whats New ESTRO 2025
- Transforming Radiation Therapy: Standard Imaging's Adaptivo In Vivo EPID Dosimetry Solution for Personalized Treatment Precision--A Comprehensive Clinical Use Case Review
- Evaluation of the Exradin A19 Ion Chamber for Reference Dosimetry in Megavoltage Photon Beams
- Evaluation of a Water-proof, Homogeneous Farmer-Type Ion Chamber for Orthovoltage and High Energy X-Rays and Electron Beams
- Commissioning and Cross-Comparison of Four Scanning Water Tanks
- Validation of the Acuros XB dose calculation algorithm versus Monte Carlo for clinical treatment plans