608-831-0025 (International)
800-261-4446 (U.S.)
Daily QA in 5 Minutes
All in One
Replaces all your Daily CT QA Phantoms. Save time and setup variability.
Better Treatment Quality
Prevent or immediately detect virtually any CT/SIM-related NC’s that can affect downstream planning, dosimetry, and delivery activities.
Integral for QA Routines
Ensure the critical elements of the CT Simulation process (people, registration hardware, couch, external lasers, internal lasers, scanner, various software systems, and their collective coincidence) remain within established conformance parameters.
New! Software for Daily QA for CT SImulator
PIPSpro Software now has a comprehensive suite of CT specific checks and data analysis tools, making daily CT QA faster, more reliable, and more comprehensive. The seamless integration empowers clinicians with a more efficient and user-friendly QA solution.
Therapist-Friendly
Light-weight. Reproducible. Efficient.
These tests provide the clinical team with daily metrics, acceptance of use, and long-term trending analysis.
Range of Tests Include:
- HU Constancy Checks
- Volume Uniformity
- Laser alignment in three axes
- Image orientation display
- Geometric scaling and isocenter laser localization
Key Features
Phantom Material and Uniformity Disk: Virtual Water
- 1.04 g/cm3 physical density
- 1.01 relative electron density to water
HU Constancy Density Plugs:
- Lung: .320g/cc, -650HU
- Liver: .497g/cc, -500HU
- Water: -Virtual Water
- Bone: 1.6g/cc, 640HU
Specifications
| Specifications | |
|---|---|
| Phantom Material/Uniformity Disk | Virtual Water |
| 1.04 g/cm3 physical density | |
| 1.01 relative electron density to water | |
| Slice Thickness Feature | Aluminum wires, 5/64" (1.984mm) diameter |
| Isocenter Localization BB | Alumina Ceramic, 3/16" (4.76mm) Dia, 3.875g/cc, ~2600HU |
| HU Constancy Density Plugs | |
| Lung | .320g/cc, ~650HU |
| Liver | .497g/cc, ~500HU |
| Water | Virtual Water |
| Bone | 1.6g/cc, 640HU |
Resources
TechNotes
Webinars and Videos
Publications
- Independent Secondary Dose Calculation for Patient-Specific Quality Assurance: Quantitative Benefit of Monte–Carlo and Custom Beam Modeling
- Routine Machine Quality Assurance Tests for a Self Shielded Gyroscopic Radiosurgery System
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Feasibility Study Using HDR 1000+ Well-Type Ionization Chambers
- Whats New ESTRO 2025
- Transforming Radiation Therapy: Standard Imaging's Adaptivo In Vivo EPID Dosimetry Solution for Personalized Treatment Precision--A Comprehensive Clinical Use Case Review
- Evaluation of the Exradin A19 Ion Chamber for Reference Dosimetry in Megavoltage Photon Beams
- Evaluation of a Water-proof, Homogeneous Farmer-Type Ion Chamber for Orthovoltage and High Energy X-Rays and Electron Beams
- Commissioning and Cross-Comparison of Four Scanning Water Tanks
- Validation of the Acuros XB dose calculation algorithm versus Monte Carlo for clinical treatment plans
We Are Here to Help
Your Wisconsin Rep is
Here to Help
Change Location
Contact Us
Online Chat
We encourage you to contact our customer service and support team.
Customer Care
For best service, login to your account.